RME Audio ADI-192 DD User's Guide Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
12
User's Guide ADI-2 © RME
9. Noise level in DS / QS Mode
The outstanding signal to noise ratio of the ADI-2 can be verified even without expensive test
equipment, by using our famous DIGICheck tool or the record level meter of Steinberg's
WaveLab. When activating the DS and QS mode, the displayed noise level will rise from -110
dB to -104 dB at 96 kHz, and –82 dB at 192 kHz. This is not a failure. This kind of measurement
measures the noise of the whole frequency range, at 96 kHz from 0 Hz to 48 kHz (RMS un-
weighted), at 192 kHz even from 0 Hz to 96 kHz.
When limiting the measured area to 22 kHz (audio bandpass, weighted) the value would be -
110 dB again. This can be verified even with RME's DIGICheck. Although a dBA weighted value
does not include such a strong bandwidth limitation as audio bandpass does, the displayed
value of –108 dB is nearly identical to the one at 48 kHz.
The reason for this behaviour is the noise shaping technology of the analog to digital convert-
ers. They move all noise and distortion to the in-audible higher frequency range, above 24 kHz.
That’s how they achieve their outstanding performance and sonic clarity. Therefore the noise is
slightly increased in the ultrasound area. High-frequent noise has a high energy. Add the dou-
bled (quadrupled) bandwidth, and a wideband measurement will show a siginificant drop in
SNR, while the human ear will notice absolutely no change in the audible noise floor.
10. SteadyClock
The ADI-2's SteadyClock technology guarantees an excellent performance in all clock modes.
Thanks to a highly efficient jitter suppression, the AD- and DA-conversion always operate on
highest sonic level, being completely independent from the quality of the incoming clock signal.
SteadyClock has been originally de-
veloped to gain a stable and clean
clock from the heavily jittery MADI
data signal (the embedded MADI
clock suffers from about 80 ns jitter).
Using the ADI-2's input signals
SPDIF and ADAT, you'll most proba-
bly never experience such high jitter
values. But SteadyClock is not only
ready for them, it would handle them
just on the fly.
Common interface jitter values in real
world applications are below 10 ns, a
very good value is less than 2 ns.
The screnshot shows an extremely jittery SPDIF signal of about 50 ns jitter (top graph, yellow).
Thanks to SteadyClock this signal turns into a clock with less than 2 ns jitter (lower graph, blue).
The signal processed by SteadyClock is of course not only used internally, but also used to
clock the digital outputs. Therefore the refreshed and jitter-cleaned signal can be used as refer-
ence clock without hesitation.